FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.gematik.isik-vitalparameter#4.0.0-rc2 (109 ms)

Package de.gematik.isik-vitalparameter
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.gematik.isik-vitalparameter@4.0.0-rc2&canonical=https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch
Url https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch
Version 4.0.0-rc2
Status draft
Date 2024-06-26
Name SD_MII_ICU_Sonstige_Pulsatile_Druecke_Generisch
Title SD MII ICU Sonstige pulsatile Druecke Generisch
Experimental False
Realm de
Type Observation
Kind resource

Resources that use this resource

StructureDefinition
https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-linksatrialer-druck SD MII ICU Linksatrialer Druck
https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-linksventrikulaerer-druck SD MII ICU Linksventrikulaerer Druck
https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-pulmonalarterieller-blutdruck SD MII ICU Pulmonalarterieller Blutdruck
https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsatrialer-druck SD MII ICU Rechtsatrialer Druck
https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck SD MII ICU Rechtsventrikulaerer Druck

Resources that this resource uses

ValueSet
https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-bodysite-observation-blutdruck VS MII ICU BodySite Observation Blutdruck
https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-method-observation-blutdruck VS MII ICU Method Observation Blutdruck


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "sd-mii-icu-sonstige-pulsatile-druecke-generisch",
  "url" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
  "version" : "4.0.0-rc2",
  "name" : "SD_MII_ICU_Sonstige_Pulsatile_Druecke_Generisch",
  "title" : "SD MII ICU Sonstige pulsatile Druecke Generisch",
  "status" : "draft",
  "experimental" : false,
  "date" : "2024-06-26",
  "publisher" : "gematik GmbH",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Observation",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation.identifier",
        "path" : "Observation.identifier",
        "mustSupport" : true
      },
      {
        "id" : "Observation.basedOn",
        "path" : "Observation.basedOn",
        "max" : "1"
      },
      {
        "id" : "Observation.status",
        "path" : "Observation.status",
        "mustSupport" : true
      },
      {
        "id" : "Observation.category",
        "path" : "Observation.category",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code",
        "path" : "Observation.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding",
        "path" : "Observation.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 2,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding.system",
        "path" : "Observation.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding.code",
        "path" : "Observation.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding.display",
        "path" : "Observation.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:sct-generic",
        "path" : "Observation.code.coding",
        "sliceName" : "sct-generic",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "code" : "75367002",
          "system" : "http://snomed.info/sct"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:sct",
        "path" : "Observation.code.coding",
        "sliceName" : "sct",
        "min" : 1,
        "max" : "1",
        "mustSupport" : true
      },
      {
        "id" : "Observation.subject",
        "path" : "Observation.subject",
        "mustSupport" : true
      },
      {
        "id" : "Observation.encounter",
        "path" : "Observation.encounter",
        "mustSupport" : true
      },
      {
        "id" : "Observation.effective[x]",
        "path" : "Observation.effective[x]",
        "mustSupport" : true
      },
      {
        "id" : "Observation.performer",
        "path" : "Observation.performer",
        "comment" : "Motivation: Dieses Feld stellt eine präzisierende Angaben zum Zweck der Qualitätsbewertung bereit",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]",
        "path" : "Observation.value[x]",
        "max" : "0",
        "mustSupport" : true
      },
      {
        "id" : "Observation.dataAbsentReason",
        "path" : "Observation.dataAbsentReason",
        "max" : "0",
        "mustSupport" : true
      },
      {
        "id" : "Observation.interpretation",
        "path" : "Observation.interpretation",
        "mustSupport" : true
      },
      {
        "id" : "Observation.bodySite",
        "path" : "Observation.bodySite",
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-bodysite-observation-blutdruck",
          "description" : "Codes describing anatomical locations. May include laterality. Subset of ValueSet for Monitoring und Vitaldaten."
        }
      },
      {
        "id" : "Observation.method",
        "path" : "Observation.method",
        "mustSupport" : true,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://gematik.de/fhir/isik/ValueSet/vs-mii-icu-method-observation-blutdruck"
        }
      },
      {
        "id" : "Observation.method.coding",
        "path" : "Observation.method.coding",
        "mustSupport" : true
      },
      {
        "id" : "Observation.method.coding.system",
        "path" : "Observation.method.coding.system",
        "mustSupport" : true
      },
      {
        "id" : "Observation.method.coding.code",
        "path" : "Observation.method.coding.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.device",
        "path" : "Observation.device",
        "mustSupport" : true
      },
      {
        "id" : "Observation.referenceRange",
        "path" : "Observation.referenceRange",
        "max" : "0",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component",
        "path" : "Observation.component",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "code"
            }
          ],
          "rules" : "open"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component.code",
        "path" : "Observation.component.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP",
        "path" : "Observation.component",
        "sliceName" : "SystolicBP",
        "min" : 0,
        "max" : "1",
        "constraint" : [
          {
            "key" : "vs-de-3",
            "human" : "If there is no value a data absent reason must be present",
            "source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
            "severity" : "error",
            "expression" : "value.exists() xor dataAbsentReason.exists()"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code",
        "path" : "Observation.component.code",
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "8480-6",
              "system" : "http://loinc.org"
            }
          ]
        }
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:loinc",
        "path" : "Observation.component.code.coding",
        "sliceName" : "loinc",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "code" : "8480-6",
          "system" : "http://loinc.org"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:loinc.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:loinc.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:loinc.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:sct",
        "path" : "Observation.component.code.coding",
        "sliceName" : "sct",
        "min" : 0,
        "max" : "1",
        "patternCoding" : {
          "code" : "271649006",
          "system" : "http://snomed.info/sct"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:sct.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:sct.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:sct.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:IEEE-11073",
        "path" : "Observation.component.code.coding",
        "sliceName" : "IEEE-11073",
        "min" : 0,
        "max" : "*",
        "patternCoding" : {
          "system" : "urn:iso:std:iso:11073:10101"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.code.coding:IEEE-11073.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.value[x]",
        "path" : "Observation.component.value[x]",
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "patternQuantity" : {
          "code" : "mm[Hg]",
          "system" : "http://unitsofmeasure.org",
          "unit" : "millimeter Mercury column"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.value[x].value",
        "path" : "Observation.component.value[x].value",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.value[x].unit",
        "path" : "Observation.component.value[x].unit",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.value[x].system",
        "path" : "Observation.component.value[x].system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.value[x].code",
        "path" : "Observation.component.value[x].code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:SystolicBP.dataAbsentReason",
        "path" : "Observation.component.dataAbsentReason",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP",
        "path" : "Observation.component",
        "sliceName" : "DiastolicBP",
        "min" : 0,
        "max" : "1",
        "constraint" : [
          {
            "key" : "vs-de-3",
            "human" : "If there is no value a data absent reason must be present",
            "source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
            "severity" : "error",
            "expression" : "value.exists() xor dataAbsentReason.exists()"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code",
        "path" : "Observation.component.code",
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "8462-4",
              "system" : "http://loinc.org"
            }
          ]
        }
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:loinc",
        "path" : "Observation.component.code.coding",
        "sliceName" : "loinc",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "code" : "8462-4",
          "system" : "http://loinc.org"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:loinc.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:loinc.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:loinc.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:sct",
        "path" : "Observation.component.code.coding",
        "sliceName" : "sct",
        "min" : 0,
        "max" : "1",
        "patternCoding" : {
          "code" : "271650006",
          "system" : "http://snomed.info/sct"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:sct.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:sct.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:sct.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073",
        "path" : "Observation.component.code.coding",
        "sliceName" : "IEEE-11073",
        "min" : 0,
        "max" : "*",
        "patternCoding" : {
          "system" : "urn:iso:std:iso:11073:10101"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.code.coding:IEEE-11073.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.value[x]",
        "path" : "Observation.component.value[x]",
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "patternQuantity" : {
          "code" : "mm[Hg]",
          "system" : "http://unitsofmeasure.org",
          "unit" : "millimeter Mercury column"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.value[x].value",
        "path" : "Observation.component.value[x].value",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.value[x].unit",
        "path" : "Observation.component.value[x].unit",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.value[x].system",
        "path" : "Observation.component.value[x].system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.value[x].code",
        "path" : "Observation.component.value[x].code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:DiastolicBP.dataAbsentReason",
        "path" : "Observation.component.dataAbsentReason",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP",
        "path" : "Observation.component",
        "sliceName" : "meanBP",
        "min" : 0,
        "max" : "1",
        "constraint" : [
          {
            "key" : "vs-de-3",
            "human" : "If there is no value a data absent reason must be present",
            "source" : "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
            "severity" : "error",
            "expression" : "value.exists() xor dataAbsentReason.exists()"
          }
        ],
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code",
        "path" : "Observation.component.code",
        "patternCodeableConcept" : {
          "coding" : [
            {
              "code" : "8478-0",
              "system" : "http://loinc.org"
            }
          ]
        }
      },
      {
        "id" : "Observation.component:meanBP.code.coding",
        "path" : "Observation.component.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:loinc",
        "path" : "Observation.component.code.coding",
        "sliceName" : "loinc",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "code" : "8478-0",
          "system" : "http://loinc.org"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:loinc.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:loinc.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:loinc.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:sct",
        "path" : "Observation.component.code.coding",
        "sliceName" : "sct",
        "min" : 0,
        "max" : "1",
        "patternCoding" : {
          "code" : "6797001",
          "system" : "http://snomed.info/sct"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:sct.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:sct.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:sct.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:IEEE-11073",
        "path" : "Observation.component.code.coding",
        "sliceName" : "IEEE-11073",
        "min" : 0,
        "max" : "*",
        "patternCoding" : {
          "system" : "urn:iso:std:iso:11073:10101"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:IEEE-11073.system",
        "path" : "Observation.component.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:IEEE-11073.code",
        "path" : "Observation.component.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.code.coding:IEEE-11073.display",
        "path" : "Observation.component.code.coding.display",
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.value[x]",
        "path" : "Observation.component.value[x]",
        "type" : [
          {
            "code" : "Quantity"
          }
        ],
        "patternQuantity" : {
          "code" : "mm[Hg]",
          "system" : "http://unitsofmeasure.org",
          "unit" : "millimeter Mercury column"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.value[x].value",
        "path" : "Observation.component.value[x].value",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.value[x].unit",
        "path" : "Observation.component.value[x].unit",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.value[x].system",
        "path" : "Observation.component.value[x].system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.component:meanBP.value[x].code",
        "path" : "Observation.component.value[x].code",
        "min" : 1,
        "mustSupport" : true
      }
    ]
  },
  "text" : {
  }
}